DVH Medical & Supplement Center
Best price

Moog EnteraLite Infinity Enteral Feeding Pump

Thumbnails
Moog EnteraLite Infinity Enteral Feeding Pump
Videos
$728.59 $1,040.89
Buy this at HPFY
You save $312.30

Why choose Infinity Pump?

  • Easy to learn and use with an intuitive design
  • Uninterrupted care while operating
  • No Annual Maintenance or Calibration
  • Washable Under Running Water

Moog EnteraLite Infinity Enteral Feeding Pump

Moog EnteraLite Infinity Enteral Feeding Pump Benefits

It maintains ± 5% accuracy at any flow rate and when operated in any orientation. This allows patients to comply exactly with prescribed feeding regimens.

It weighs less than 1 pound and is easily carried in a custom-designed carry pack for extended use. Thus, it results in fewer limitations to a patient’s normal lifestyle, which may lead to increased feeding schedule compliance.

Features an intuitive design and interface that can be quickly and easily mastered, allowing the caregiver to focus on other areas of care. The easy-to-load cassette allows for consistent use.

It performs consistently under a wide variety of conditions. It does not require regularly scheduled maintenance or calibration and can be cleaned with warm, soapy water.

Priming and Loading the Disposable Set

Step 1

  • If you are using the Infinity Spike set, remove the protective cover from the connector and insert the connector tip into the compatible port on the enteral formula container (image A). Secure the connector by tightly screwing threaded components together. If you are using the 500 mL or 1200 mL disposable set, hold the bag’s funnel upright and pour in the feeding formula. Close the cap tightly and hang the bag (image B).

Step 2

  • Remove the protective cover from the feeding tube connector(image C).

Step 3

    • PUMP PRIMING: Loop the silicone tubing around the pump wheel, stretching lightly. Seat the cassette into the pump and close the door (image D). Turn the pump on by pressing and holding the ON/OFF key until the pump beeps (image E). Then, press and hold the PRIME key until the formula reaches the feeding tube connector (image F).
    • IF MANUAL PRIMING: Gently pinch teal-colored tubing below the “ ” symbol (image G). While lifting, gently squeeze the bag simultaneously to assist fluid flow. Hold this position until the formula reaches the feeding tube connector. Loop silicone tubing around the pump wheel, stretching lightly. Seat cassette into the pump (image D). Close the pump door.
  • FOR BACKPACK USE: Turn the bag upside down and tilt the bag to keep air at the tubing port (image H). Gently pinch teal-colored tubing below the symbol (image G). While lifting, gently squeeze the bag at the same time to assist fluid flow. Hold this position until the formula reaches the feeding tube connector.

How to use Infinity Enteral Feeding Pump?

  1.  If you are using the Safety Screw Connector or Spike set with a vented bottle or pre-filled bag, remove the protective cover from the tip, then insert the tip into the enteral feeding formula exit port of the container. Using the Safety Screw Connector set, secure the tip by tightly screwing threaded components together. If you are using the 500ml or 1200ml disposable set, hold the bag upright and pour in the enteral feeding solution. Then, close the cap securely.
  2. Remove the protective cover from the barbed adapter. If using a pole clamp, place the protective cover in the groove on the back of the clamp.
  3. Turn the bag upside down and gently squeeze. Tilt bag as needed to evacuate air through the tubing port.
  4. Gently pinch the teal-colored tubing below the drop symbol. Hold this position until the air dissipates from the tubing. Gently squeeze the bag at the same time to assist fluid flow. If the fluid does not flow, the pinch pressure may be too strong.
  5. Loop silicone tubing around the pump wheel, stretching it lightly. Seat the cassette into the pump. Close the pump door.
  6. To turn the pump on, press and hold the ON/OFF key for 1.5. While the pump runs through a self-test, the display will light and an audible alarm will sound as the pump displays the nine-digit number three digits at a time for one second each. The display will then show the letter ‘R’ followed by a number, which is the software revision. Next, all segments of the display will show for 2 seconds. Verify that all display segments and symbols are active. The self-test is complete, and the pump will display the last programmed rate and be in pause mode. If any air is still in the tubing, continue to Step 7 to use the prime pump feature.
  7. Press and hold the PRIME key. The alarm will sound once, and the pump will begin pumping at the maximum rate of 600 ml/hr. The display will read “TO STOP, LET GO.” Once all air is removed from the tubing, release the key. The pump will stop, the display will revert to the last programmed rate, and the pump will be in pause mode.

Infinity Enteral Feeding Pump Components

  1. Door
  2. Pump Wheel
  3. Display
  4. Tab
  5. Upstream Pressure Sensor
  6. Air Sensor
  7. Downstream Pressure Sensor
  8. Receptacle for Cassette
  9. Keypad

How to Clean Enteralite Infinity Feeding Pump?

Unplug the Infinity AC Adapter/Charger from the pump and turn the pump off.

Rinse the pump by holding it under a stream of warm water. The pump may also be cleaned with standard dish soap and a nonabrasive sponge or soft cloth

Use a cotton swab to clean the pathways of the cassette and to remove any residue on the pump wheel roller pins.

Dry with a clean cloth. Ensure the Moog Infinity pump is completely dry before plugging it into an electrical outlet.

Cautions:

  • It is important to keep the air sensor free of debris, including spilled fluids or food that may adhere to it, and to prevent the detection of air in the tubing.
  • Use a cotton swab to clean the pathways of the cassette receptacle. (For further cleaning instructions, refer to the operator’s manual.)
  • When using a programmed dose, infinite dose, or interval feeding setting, the volume of food in the bag/bottle should be monitored throughout the feeding cycle to ensure the patient has received the appropriate dose.

Enteralite Infinity Pump Manual & Guides

Frequently Bought Together

Also available (separately):

Frequently Asked Questions

1. Can I use my own homemade, blenderized food in the Infinity pump?

Use only commercially prepared feeding solutions formulated for pumps prescribed by a health care professional. Do not use homemade feeding solutions in the Infinity pump.

2. What are the Infinity Delivery Sets made of? Do they contain Latex?

Infinity Delivery Sets are made with materials that DO NOT contain the plasticizer DEHP or natural rubber latex.

Infinity Feeding Pump Specifications

Particular Dimension
Size 4.05″H (10.3cm) x 5.65″W (14.4cm) x 1.95″D (4.9cm)
Weight 14.4oz (408gm)
Flow rate range 0.1 to 600ml/hr
Flow rate increment 0.1ml/hr from 0.1 to 10m/hr, 1ml/hr from 10 to 600ml/hr
Accuracy +/- 5%
Dose range 0.1ml to 3000ml or infinite dose
Dose increment 0.1ml from 0.1 to 10ml, 1ml from 10 to 3000ml
Battery Lithium Ion, 24 hour life @ 125ml/hr
Battery charge time 6 hours
Operating orientation Any
Maintenance No annual maintenance or calibration required

Infinity Enteral Feeding Pump Warranty

2-year warranty

Product Videos

YOU MAY ALSO LIKE

Added to wishlistRemoved from wishlist 0
Add to compare

Calcium (citrate)

Added to wishlistRemoved from wishlist 0
Add to compare

NAC 60 Capsules

Added to wishlistRemoved from wishlist 0
Add to compare
Best price

Oval Induction Loop Receiver

Original price was: 179.55 $.Current price is: 123.89 $.
Added to wishlistRemoved from wishlist 0
Add to compare

ProOmega 2000

Show next
Exit mobile version